The only NIOSH-approved 30-minute Air-Purifying Escape Respirator for CO (Carbon Monoxide) and CBRN

SCAPE CO/CBRN-30

Technical Specifications

Test

Agent

Mustard (HD) Vapor

Mustard (HD) Liquid

Sarin (GB) Vapor

Challenge

Concentration

50 mg/m3

0.43-0.86 ml

210 mg/m3

Service

Time

>30

>30

>30

CO CHALLENGE CONCENTRATION

3600 ppm

MAXIMUM ALLOWANCE PEAK EXCURSION

(DETECTED CO LEVELS IN PARTS PER

MILLION) AT 30 MINUTE IDENTIFIED

SERVICE LIFE DURATION

500 ppm

RESULTING MAXIMUM PEAK

EXCURSION (DETECTED CO

LEVELS IN PPM)

<200ppm

CO CHALLENGE CONCENTRATION

3600 ppm

MAXIMUM ALLOWABLE

CONCENTRATION TIME

(CT) (PPM-MINUTES) FOR 30 MINUTE

IDENTIFIED SERVICE LIFE DURATION**

12,075

RESULTING CONCENTRATION

TIME (CT) (PPM-MINUTES)

AT 30 MINUTES)

<200

SCape® CO/CBRN3030 System Level Agent (SMARTMAN)

SCape® CO/CBRN30 Carbon Monoxide (CO) Penetration Performance

To ensure strict adherence to safety protocols and usage, purchases of this product can only be made through a request form.



The only NIOSH-approved 30-minute Air-Purifying Escape Respirator for CO (Carbon Monoxide) and CBRN

SCAPE CO/CBRN-30

Technical Specifications

SCape® CO/CBRN3030 System Level Agent (SMARTMAN)

Test

Agent

Mustard (HD) Vapor

Mustard (HD) Liquid

Sarin (GB) Vapor

Challenge

Concentration

50 mg/m3

0.43-0.86 ml

210 mg/m3

Service

Time

>30

>30

>30

SCape® CO/CBRN30 Carbon Monoxide (CO) Penetration Performance

CO CHALLENGE CONCENTRATION

3600 ppm

MAXIMUM ALLOWANCE PEAK EXCURSION

(DETECTED CO LEVELS IN PARTS PER

MILLION) AT 30 MINUTE IDENTIFIED

SERVICE LIFE DURATION

500 ppm

RESULTING MAXIMUM PEAK

EXCURSION (DETECTED CO

LEVELS IN PPM)

<200ppm

CO CHALLENGE CONCENTRATION

3600 ppm

MAXIMUM ALLOWABLE

CONCENTRATION TIME

(CT) (PPM-MINUTES) FOR 30 MINUTE

IDENTIFIED SERVICE LIFE DURATION**

12,075

RESULTING CONCENTRATION

TIME (CT) (PPM-MINUTES)

AT 30 MINUTES)

<200

To ensure strict adherence to safety protocols and usage, purchases of this product can only be made through a request form.

Request Now

To ensure strict adherence to safety protocols and usage, purchases of this product can only be made through a request form.

Request Now

The only NIOSH-approved 30-minute Air-Purifying Escape Respirator for CO (Carbon Monoxide) and CBRN

SCAPE CO/CBRN-30

Technical Specifications

SCape® CO/CBRN3030

System Level Agent (SMARTMAN)

Test

Agent

Mustard (HD) Vapor

Mustard (HD) Liquid

Sarin (GB) Vapor

Challenge

Concentration

50 mg/m3

0.43-0.86 ml

210 mg/m3

Service

Time

>30

>30

>30

Test

Agent

Mustard (HD) Vapor

Mustard (HD) Liquid

Sarin (GB) Vapor

Challenge

Concentration

50 mg/m3

0.43-0.86 ml

210 mg/m3

Service

Time

>30

>30

>30

SCape® CO/CBRN30

Chemical Test Agents (Filter Gas Life)

Test

Agent

(Chemicals)

Ammonia (NH3)

Cyanogen Chloride (CNCl)

Cyclohexane (C6H12)

Formaldeh-yde (CH2O)

Hydrogen Cyanide (HCN)

Hydrogen Sulfide (H2S)

Nitrogen Dioxide (NO2)

Phosgene (COCI2)

Phosphine (PH3)

Sulfur Dioxide (SO2 )

Challenge

Concentration

(ppm) (64 Ipm at both 25% & 80% RH)

1250

150

1300

250

470

500/1500

100

125

150

750

Allowable Breakthrough

(ppm)

25

2

10

10

10

30

1

1.25

0.5

5

Service

Time

(min)

>30

>30

>30

>30

>30

>30

>30

>30

>30

>30

Test

Agent

(Chemicals)

Ammonia (NH3)

Cyanogen Chloride (CNCl)

Cyclohexane (C6H12)

Formaldeh-yde (CH2O)

Hydrogen Cyanide (HCN)

Hydrogen Sulfide (H2S)

Nitrogen Dioxide (NO2)

Phosgene (COCI2)

Phosphine (PH3)

Sulfur Dioxide (SO2 )

Challenge

Concentration

(ppm) (64 Ipm at both 25% & 80% RH)

1250

150

1300

250

470

500/1500

100

125

150

750

Allowable Breakthrough

(ppm)

25

2

10

10

10

30

1

1.25

0.5

5

Service

Time

(min)

>30

>30

>30

>30

>30

>30

>30

>30

>30

>30

SCape® CO/CBRN30

Chemical Test Agents (Filter Gas Life)

Test

Agent

(Chemicals)

Acetic Acid [CH3COOH]

Acrolein [C3H40]

Acrylonitrile [C3H3N]

Benzene [C6H6]

Boron Trifluoride [BF3]

Chlorine [Cl2]

Chlorine Dioxide [CIO2]

Fluorine [F2]

Hexane [C6H14]

Hydrogen Chloride [HCl]

Hydrogen Fluoride [HF]

Nitric Acid [HNO3]

Toluene [C6H5CH3]

Challenge

Concentration

(ppm) (64 Ipm at both 25% & 80% RH)

1000

100

1000

1000

100

1000

1000

100

2000

500

70

100

1000

Allowable Breakthrough

(ppm)

5

1

10

1

5

5

2

5

10

5

3

2

10

Service

Time

(min)

>30

>30

>30

>30

>30

>30

>30

>30

>30

>30

>30

>30

>30

Test

Agent

(Chemicals)

Acetic Acid [CH3COOH]

Acrolein [C3H40]

Acrylonitrile [C3H3N]

Benzene [C6H6]

Boron Trifluoride [BF3]

Chlorine [Cl2]

Chlorine Dioxide [CIO2]

Fluorine [F2]

Hexane [C6H14]

Hydrogen Chloride [HCl]

Hydrogen Fluoride [HF]

Nitric Acid [HNO3]

Toluene [C6H5CH3]

Challenge

Concentration

(ppm) (64 Ipm at both 25% & 80% RH)

1000

100

1000

1000

100

1000

1000

100

2000

500

70

100

1000

Allowable Breakthrough

(ppm)

5

1

10

1

5

5

2

5

10

5

3

2

10

Service

Time

(min)

>30

>30

>30

>30

>30

>30

>30

>30

>30

>30

>30

>30

>30

SCape® CO/CBRN30 Carbon Monoxide (CO) Penetration Performance

CO CHALLENGE CONCENTRATION

3600 ppm

MAXIMUM ALLOWANCE PEAK EXCURSION

(DETECTED CO LEVELS IN PARTS PER

MILLION) AT 30 MINUTE IDENTIFIED

SERVICE LIFE DURATION

500 ppm

RESULTING MAXIMUM PEAK

EXCURSION (DETECTED CO

LEVELS IN PPM)

<200ppm

CO CHALLENGE CONCENTRATION

3600 ppm

MAXIMUM ALLOWANCE PEAK EXCURSION

(DETECTED CO LEVELS IN PARTS PER

MILLION) AT 30 MINUTE IDENTIFIED

SERVICE LIFE DURATION

500 ppm

RESULTING MAXIMUM PEAK

EXCURSION (DETECTED CO

LEVELS IN PPM)

<200ppm

CO CHALLENGE CONCENTRATION

3600 ppm

MAXIMUM ALLOWABLE

CONCENTRATION TIME

(CT) (PPM-MINUTES) FOR 30 MINUTE

IDENTIFIED SERVICE LIFE DURATION**

12,075

RESULTING MAXIMUM PEAK

EXCURSION (DETECTED CO

LEVELS IN PPM)

<200

CO CHALLENGE CONCENTRATION

3600 ppm

MAXIMUM ALLOWABLE

CONCENTRATION TIME

(CT) (PPM-MINUTES) FOR 30 MINUTE

IDENTIFIED SERVICE LIFE DURATION**

12,075

RESULTING MAXIMUM PEAK

EXCURSION (DETECTED CO

LEVELS IN PPM)

<200

To ensure strict adherence to safety protocols and usage, purchases of this product can only be made through a request form.